Method-based inspection forms
Separate, standard-referenced form structures for VT, PT, MT, UT, RT and destructive tests.
For destructive and non-destructive testing bodies: test requests, samples, method-based forms, personnel eligibility, device traceability, report and invoicing management.
NDT and DT inspection software combines test request, sample or field intake, method and personnel eligibility, device traceability, measurement records, technical evaluation, report and invoicing steps in the same work order.
In Vizyon NDT & DT, methods such as VT, PT, MT, UT and RT are managed with separate form and authorization rules. During assignment, the person's method, level and sector information and the validity record of the device to be used are checked. Measurements, films, images and reports created in the field or laboratory are linked to the same inspection record.
Official sources:
ISO — ISO 9712 NDT personnel qualification and certification ISO — ISO/IEC 17020 requirements for inspection bodies ISO — ISO/IEC 17025 testing and calibration laboratories
For non-destructive and destructive testing bodies, field teams, laboratory personnel, Level II/III evaluators and operations teams.
VT, PT, MT, UT, RT and destructive tests; each method is tracked separately with its own form, personnel, device and report rules.
The person's method, level, sector and validity record is evaluated together with the scope of the work order.
Sample or part identity, field form, measurements, photos, RT films, UT scans, device record and report are linked to the same job.
A single flow from test request to sample and field tracking, method-based inspection to e-signed report and invoicing.
A request and quotation are created with the selection of method, standard and scope.
Samples are barcoded; for field work, team and device assignment is made.
Measurements, films and images are added to method-based forms.
The Level II/III evaluation is completed; an e-signed report is produced.
Invoices are prepared from completed tests; the film/image archive is stored together with the report.
You can explore the product's core functions and everyday use cases below.
Separate, standard-referenced form structures for VT, PT, MT, UT, RT and destructive tests.
Level-, method- and sector-based certificates are tracked; eligibility is checked at assignment.
In which area and method each person is authorized is defined individually.
Unauthorized assignments are blocked; workload, test count and performance are tracked.
Calibration certificates and their validity are linked to the device used in the report.
Every step from intake to report is tracked with barcode/QR and a time record.
RT films, UT scans and field photos are stored linked to the report.
Offline field records and laboratory work orders advance in the same flow without duplicate entry.
The open, in-field and completed statuses of jobs with assigned teams and devices are tracked on a single screen.
Separate invoices for NDT/DT work are prepared from test, unit-price and period data.
Activity, half-life, license and usage records of RT source devices are tracked.
The e-signed report is shared digitally via the customer panel and verification link.
The customer application is evaluated and returns to the quotation and project on the same record.
The field form and the customer report are produced linked to a single inspection record.
Counters run automatically by method, period and test type; the main number is preserved on revision.
Report templates specific to welding and joining method approval tests, with scope control.
Cover and test reports are merged in the correct order into a single e-signed PDF package.
Until the person approves the impartiality statement, their signature is not applied to the work order and report.
Examine method-based reporting, the work order flow and personnel assignment controls in detail.
Examine how method, personnel, device and report traceability is established in the same system.
Follow the work order flow from request, scope, personnel and device assignment to field records and the report.
Evaluate step by step the checks of personnel method, level, sector and certificate validity.
Basic questions about method scope, ISO 9712 records, field use and report evidence.
No. The software tracks existing certificate, method, level, sector and validity records. Personnel certification and technical authorization are the responsibility of the relevant authorized bodies.
Separate fields, acceptance criteria and report templates can be defined for each method. Common customer, part and work order information is carried to the relevant method record without re-entry.
Validity and scope information is checked during assignment. A missing or expired record is flagged for review by an authorized user and unsuitable assignment is blocked.
In the offline field flow, forms, measurements, photos and notes are recorded on the device; when connectivity returns they sync to the relevant work order.
Films, scans and field images are attached to the inspection record; the report is archived together with the part or sample identity and the device record used.
The modules connect on the same customer, personnel, project, document, authorization and activity records.
Let's plan a 30-minute demo with your own scope, record structure and report formats.